page_banner

D-120W

Adjustable iPad Stand, Tablet Stand Holders。

D-120W

·AC input voltage range selected by switch·Small volume,low weight,high efficiency·Protections:short circuit/over load/over voltage·LED indicator for power on·100% full load burn-in test·2 Years warranty


Product Detail

FAQ

Product Tags

D-120W series normal dual switching power supply

Features:

·AC input voltage range selected by switch

·Small volume,low weight,high efficiency

·Protections:short circuit/over load/over voltage

·LED indicator for power on

·100% full load burn-in test

·2 Years warranty

Model

D-120A

D-120B

D-120C

 

 

 

output

DC voltage

CH1:5V

CH2:12V

CH1:5V

CH2:24V

CH1:12V

CH2:24V

Voltage tolerance

±2%

+5%~-8%

±3%

+6%~-8%

±3%

+7%~-8%

Rated current

12A

5A

6A

4A

5A

2.5A

Current range

2~12A

0.5~5A

1~6A

0.4~4A

1~5A

0.4~2.5A

Rated power

120W

126W

120W

Ripple&noise

80mvp-p

120mvp-p

80mvp-p

150mvp-p

120mvp-p

150mvp-p

DCvoltage ADJ.range

CH1:-9%~+10%

 

 

input

Voltage range

90~132VAC/180~264VAC(selected by switch),255~373VDC

frequency

47~63HZ

AC current

2.8A/115VAC,1.6A/230VAC

efficiency

78%

80%

81%

Inrush current

Cold start current25A/115VAC,50A/230VAC

Leakage current

< 3.5mA/240VAC

 

protection

overload

Rated output power110%~150start over load protection

protection type:cutoff output,recovery after restart power

over voltage

CH1:115~135%

protection type:cutoff output,recovery after restart power

environment

Working temp,humidity

-10℃~+60℃,20%~90%RH

Storage temp,humidity

-20℃~+85℃,10%~95%RH non-condensing

Withstand vibration

10~500HZ,2G10min/1cycle,period for 60 minutes,each axes

safety

Withstand voltage

I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC

Fit standard

Safety standard

Compliance to UL1012

EMC standard

Compliance to EN55022,CLASSA

others

Dimension

199*110*50mm(L*W*H)

Weight/packing

0.85kg/24pcs/21kg/0.043m³/1.51CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

                   

  • Previous: